Q: Will this cell work both the normal power center for the Pentair Intellichlor and can it also get powered from control board like Intellitouch or Easytouch? Can it also get connected to Intellitouch rs-485 communication wires?

Asked by: Dillon H - 4/30/2024
A: The APEX P40 can be powered from an Intellichlor Power Center.
Regarding the Intellitouch or Easytouch, the cell still connects to a Pentair Power Center and the Intellitouch or Easytouch will merely control the Power Center.
The APEX P40 has no provision for connecting to or communicating via RS-485 data lines.
Was this answer helpful?  13 of 15 Customer(s) found this Answer helpful.
Answer provided by: Steve (4/30/2024)

Q: Where can you purchase the "replaceable inner cell" for the P40?

Asked by: Charles - 6/7/2024
A: You can find that item here: P40 Inner Cell
Was this answer helpful?  13 of 15 Customer(s) found this Answer helpful.
Answer provided by: Customer Service Team (6/10/2024)

Q: I just installed my apex p40 chlorinator. And I am getting red light to check salt. And there is a warning to add water. Any idea how to fix this.

Asked by: will woods - 6/6/2024
A: You can take a look at the troubleshooting in the manual (here)


You can also see the system's service diagnostics (here)


You can also get in touch with our support team at apexpool.com/support
Was this answer helpful?  3 of 7 Customer(s) found this Answer helpful.
Answer provided by: Customer Service Team (6/10/2024)

Q: How do I increase % chlorine production

Asked by: Paul - 6/8/2024
A: The chlorine output can be increased by hitting the "+" button on the controls. This changes the system in 10% increments.
Was this answer helpful?  3 of 3 Customer(s) found this Answer helpful.
Answer provided by: Customer Service Team (6/10/2024)

Q: Does it adjust its chlorine output based on pool mod and spa mode as the Pentair IC40 does?

Asked by: RJS - 9/24/2024
A: The Apex P40 Aftermarket Replacement Cell, along with the P20 and P60 models, can receive power from a Pentair automation system, but controlling and adjusting the cell can only be performed via the cell's attached control module. The APEX P20, 40, and 60 have no provisions for connecting to or communicating via RS-485 data lines.
Consequently, changing between pool and spa modes with the automation system's controls will not change the operation of the Apex cell.
Was this answer helpful?  3 of 3 Customer(s) found this Answer helpful.
Answer provided by: Steve (9/27/2024)

Q: What is the lifespan of the Apex P40? (For comparison, the Pentair IC40 lifespan is specified to be 10,000 hours or about 5 years of normal use).

Asked by: Keith - 6/5/2024
A: A cell's lifespan is ultimately unique to the pool it is used on, based on the size of the pool, how long the equipment runs every day, the season length, how its water chemistry is maintained, the usage of swimmers, its environment, and more. If sized and used properly, a cell can last years longer than its warranty period.
Was this answer helpful?  2 of 24 Customer(s) found this Answer helpful.
Answer provided by: Customer Service Team (6/10/2024)

Q: What is the length of the salt cell?

Asked by: Barry Klein - 6/7/2024
A: The cell has the same length and same threads as the original. It is approximately 12.5" from end to end.
Was this answer helpful?  2 of 2 Customer(s) found this Answer helpful.
Answer provided by: Customer Service Team (6/11/2024)

Q: I am looking to use this as a replacement cell in my Pentair system. I see the power is compatible but automation will not occur. Will this cell be able to be scheduled to run at the same time that my automated pump will run, or does it have to be manually turned on each time I use it? Thanks!

Asked by: Keith - 1/12/2025
A: The APX PERFORMANCE P40 Aftermarket Replacement Cell which fits Pentair® IntelliChlor® systems, along with the P20 and P60, will connect to and can be powered by a Pentair® automation device.
These aftermarket replacement cells will power on and off as controlled by the automation unit. However, you will not be able to control other functions of the cell, eg. raise or lower the chlorine output, from the automation unit. Such functions will still need to be conducted manually via the cell's control module.
Was this answer helpful?  2 of 2 Customer(s) found this Answer helpful.
Answer provided by: Alan (1/14/2025)

Q: What is your refund policy?

Asked by: Judy - 6/9/2024
A: Our refund policy can be found in the terms at the bottom of the page or here: Refund Policy
Was this answer helpful?  1 of 1 Customer(s) found this Answer helpful.
Answer provided by: Customer Service Team (6/10/2024)

Q: Can you cut the cord and power the cell with 110v or 220v AC? Thanks, Jason

Asked by: Jason Haywood - 5/14/2025
A: Absolutely, not. The APX PERFORMANCE P40 Aftermarket Replacement Cell is intended to plug into a Pentair-style Power Center in order to operate.
Was this answer helpful?  1 of 1 Customer(s) found this Answer helpful.
Answer provided by: Steve (5/14/2025)

Q: Does the P-cell P40 have auto polarity change for the cell plates? The Pentair has this which helps to reduce calcium scale build-up, and wondering if your units utilize the same method?

Asked by: Jon R - 7/25/2025
A: Yes, the APX PERFORMANCE P-Series of Aftermarket Replacement Cells employ polarity switching to reduce the pace of deposit formation on the cell plates.
Was this answer helpful?  1 of 1 Customer(s) found this Answer helpful.
Answer provided by: Steve (7/25/2025)

Q: What is the best way to clean my p11-40r salt cell? Thank you

Asked by: Carl Ashcroft - 7/23/2025
A: Instructions for cleaning the APX PERFORMANCE P40 Aftermarket Replacement Cell can be found on page 13 of the User Guide
Was this answer helpful?  0 of 1 Customer(s) found this Answer helpful.
Answer provided by: Steve (8/1/2025)

Q: I see mention that there is no communication between the APEX P40 and the Intellichlor system for automations. Does this also mean my Intellichlor will no longer show the water temperature, salt level, and salt cell output settings?

Asked by: Brian Taylor - 4/14/2026
A: The APX PERFORMANCE P40 Aftermarket Replacement Cell which fits Pentair® IntelliChlor® systems, along with the P20 and P60, will connect to and can be powered by a Pentair® automation device.
These aftermarket replacement cells will power on and off as controlled by the automation unit. However, you will not be able to control other functions of the cell, eg. raise or lower the chlorine output, from the automation unit. Such functions will still need to be conducted manually via the cell's control module
Was this answer helpful?  0 of 1 Customer(s) found this Answer helpful.
Answer provided by: Steve (4/22/2026)

Q: How do I replace the temp sensor on the CFICGEN20-RC

Asked by: LT313 - 6/30/2025
A: On these units, a bad temperature sensor will call for replacing the flow switch. The water temperature sensor is incorporated into the flow switch.
Was this answer helpful?  0 of 0 Customer(s) found this Answer helpful.
Answer provided by: Steve (6/30/2025)

Q: I am trying to replace an Pentair IC40. Do the Apex P40 and P60 have the same dimensions? Can I drop in either in my current plumbing configuration?

Asked by: Lee - 2/22/2026
A: Just as the Pentair IC20, 40, and 60 are physically interchangeable, ie. length, threads, etc. are the same, the APX PERFORMANCE P Series Aftermarket Replacement Cells are identical in their dimensions and fit as well.
Was this answer helpful?  0 of 0 Customer(s) found this Answer helpful.
Answer provided by: Steve (3/18/2026)

Q: My cell was shipped without a user guide. Can I download one or where can I go to find it

Asked by: Brad Latour - 4/2/2026
Was this answer helpful?  0 of 0 Customer(s) found this Answer helpful.
Answer provided by: Steve (4/3/2026)

Q: Can your flow be reversed? I have a client that has a tight install and with current IC40 install vertically, with their built in flow switch rotated. Basically it flows in the opposite direction of what the arrow points on the unit housing.

Asked by: NC Pool Guy - 5/9/2026
No Answers have been submitted yet.

Q: I have an Pentair intellitouch. Will your cell work with it? I don't care about data transmission or anything I just want to make sure it will generate chlorine if I buy it. Does it draw power from the intellitouch unit?

Asked by: Aaron Bell - 6/15/2026
A: This cell has a cable which is meant to be hooked up to the same cell cable connection that an existing cell is currently getting power from. Once connected, the P40 cell will power up and will be controlled by its onboard controller - as you mention, it is not designed to communicate with an automation system and doesn't utilize a RS-485 connection.
Was this answer helpful?  0 of 0 Customer(s) found this Answer helpful.
Answer provided by: Customer Service Team (6/16/2026)

Q: Is there a way to calibrate the salinity level. It is showing 4700 and marking high salt but I tested with a tds meter and it is reading 2900

Asked by: Bryan - 7/1/2026
A: While there is a way to calibrate this cell, it is very rarely needed. It would not be suggested to judge by a TDS meter. You would want to use titration drops to chemically determine the precise salinity level if you were to get the most accurate reading with which to calibrate the cell by. If a reading based on titration drops is very off, please contact our support team so they can guide you through the calibration process.
Was this answer helpful?  0 of 0 Customer(s) found this Answer helpful.
Answer provided by: Customer Service Team (7/23/2026)

Q: your length is stated in the FAQ's as 12.6 inches however the Pentair IC40 is 17 inches that's a 4.5 inch difference how do you consider this a direct replacement if it is too short ?

Asked by: scooter758 - 7/15/2026
A: The two different cells are a direct swap and require no modifications. Perhaps you are looking at one person describe the length of the cell body from threads to threads, and perhaps you are looking at another person describe the length of a cell with its plumbing unions attached. This cell will go in as a replacement as a direct swap - simply unscrew the old cell from its unions and screw this cell in place.
Was this answer helpful?  0 of 0 Customer(s) found this Answer helpful.
Answer provided by: Customer Service Team (7/16/2026)

Q: After swapping out the old Pentair IC40, does the APX 40 require any calibration? Or do I just power it up , and let it work?

Asked by: Tony - 7/23/2026
A: When you install this product, you should be able to power it up and it will begin working if you have the proper salinity level in the water so it can generate chlorine normally. If by calibration, you mean adjusting its chlorine output level - yes, you should plan on watching it over the first week or so, doing regular water chemistry tests and adjusting the output until you maintain a consistent 1-3ppm free chlorine level. If by calibration you mean calibrating its salinity reading - no, it would be very atypical to need to do this.
Was this answer helpful?  0 of 0 Customer(s) found this Answer helpful.
Answer provided by: Customer Service Team (7/23/2026)

Q: On my APEX (APX-P11-40R) I have a red flashing cell light. Water flow, salt, and generating lights are green. What can be the problem?

Asked by: Scott - 8/22/2026
A: For a red "check cell" light, the most common cause is calcium scale or debris inside the cell, but first you should independently confirm you pool water's salinity to be 3000-4000ppm ideally. If the salinity is good, likely the cell should be inspected / cleaned.

Turn the system off and inspect the cell from both ends. First rinse it thoroughly with a strong garden-hose spray; then follow the instructions in the manual to clean the cell. Note that if there is still "fizzing" when cleaning the cell after 10 minutes or so, you may need to dispose of the cleaning solution, mix up a new, batch, and clean the cell again (sometimes more than one cleaning in a row is required to dissolve excessive scaling).

If the warning remains after the cell is clean and the water's salinity is confirmed, press the "+" and "-" keys together to enter the diagnostic mode, which will provide the displayed voltage, current, salt reading, and cell runtime to our support team.
Was this answer helpful?  0 of 0 Customer(s) found this Answer helpful.
Answer provided by: Customer Service Team (8/25/2026)

Q: Hello, is this a direct plumbing fit replacement for the Pentair iChlor30 ? Thank you

Asked by: Steve Gormont - 8/28/2026
A: The APX P40 chlorinator can be made to replace the older Pentair iChlor 30, although re-plumbing is necessary due to differences in dimensions. The APX P20, P40, and P60 cells are the length of IntelliChlor cells, and iChlor cells are shorter. So there would need to be a small amount of plumbing work done to lengthen the gap between your existing fittings. One way among others that this could be done is by making some cuts in the plumbing nearby, and using an off the shelf coupler to reattach your plumbing in a way that creates a larger distance between your current cell fittings.



So other than the length of the cell, these items can utilize the same threaded fittings and the same power center. Please let us know if you have more questions.
Was this answer helpful?  0 of 0 Customer(s) found this Answer helpful.
Answer provided by: Customer Service Team (8/28/2026)

Q: Can I get a replacement power cord for p 40 salt cell?

Asked by: Paul - 8/28/2026
A: The cord is not listed as a separate part. Please contact our support team to see if there are possibly any other options.
Was this answer helpful?  0 of 0 Customer(s) found this Answer helpful.
Answer provided by: Customer Service Team (8/28/2026)

Q: is APX Performance P40 model inner cell replacement the APX-P11-40R? where is the link so you can replace the Inner cell?

Asked by: mike - 10/31/2026
A: Yes, the APX-P11-40R inner replacement cell is what you would purchase once your current cell is depleted. This allows you to restore chlorine generation at a fraction of the price of the original salt cell. The link can be found here: https://apxpool.com/apx-p-series-inner-replacement-cell-for-the-p40-housing-and-electrode-only.html
Was this answer helpful?  0 of 0 Customer(s) found this Answer helpful.
Answer provided by: Customer Service Team (11/2/2026)